I have this device Bus 001 Device 008: ID 152d:2329 JMicron Technology Corp. / JMicron USA Technology Corp. http://www.eagletechusa.com/External_Enclosure/ET-CS2XMESU2-BK.htm which is blacklisted in libatasmart: http://git.0pointer.de/?p=libatasmart.git;a=blob;f=atasmart.c;h=3ff033418a4d8e27f2828a9c0b474d1db9e545be;hb=54f846c2115e7addf5468a9c10ecf9ba844b946e#l2506 If I comment out the blacklist entry, the device indeed chokes (as in, it disconnects) when libatasmart is trying to read SMART status. However, it works fine with smartmontools # smartctl -a /dev/sdb smartctl 5.39 2009-11-30 r2990 [x86_64-redhat-linux-gnu] (local build) Copyright (C) 2002-9 by Bruce Allen, http://smartmontools.sourceforge.net === START OF INFORMATION SECTION === Model Family: Western Digital Scorpio Blue Serial ATA family Device Model: WDC WD5000BEVT-22ZAT0 Serial Number: WD-WXE0A89K3530 Firmware Version: 01.01A01 User Capacity: 500,107,862,016 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Mon Dec 14 10:03:51 2009 EST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (13200) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 154) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x303f) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 100 253 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0027 182 180 021 Pre-fail Always - 1875 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 17 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0 7 Seek_Error_Rate 0x002e 100 253 000 Old_age Always - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 4 10 Spin_Retry_Count 0x0033 100 253 051 Pre-fail Always - 0 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 15 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 7 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 42 194 Temperature_Celsius 0x0022 121 109 000 Old_age Always - 26 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0009 100 253 051 Pre-fail Offline - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.
Use of freedesktop.org services, including Bugzilla, is subject to our Code of Conduct. How we collect and use information is described in our Privacy Policy.